IGU-16HR 3C 2Hz

IGU-16HR 3C 2Hz
IGU-16HR 3C 2Hz Seismograph with 15 s ~ 500 Hz bandwidth
Conveniently and quickly form various networked seismic arrays,
Combined with active and passive source methods,
obtain massive data for high-density array spatiotemporal measurement (DAM).
Suitable for scientific research and enterprise survey needs in different scale regions.

Main Features

Integrated Sensor, Digitizer, Communication and Control Capabilities for Efficient and Stable Field Deployment
Built-In DT-SOLO 2Hz Geophone Accurately Captures Deep Low- Frequency Signals
Precision Manufacturing Ensures Accurate and Consistent Instrument Transfer Function
IP68-Rated, Low Power,Long Battery Life,and Ultra-Wide Operating Temperature,Ensuring Reliability in Harsh Conditions
Improves Signal-To-Noise Ratio, Enabling Detection of Ultra-Weak Seismic Signals
Enhanced Circuit Protection Significantly Extends Instrument Lifespan
Open Data Transmission Protocol Allows Seamless Integration with Mainstream Processing Platforms

Peripheral Equipment

Data download cable with parallel USB 3.0 high-speed data transfer;
4-port USB Hub supporting simultaneous data download from 4 devices;
Power adapter supports 4A current charging;
Supports 7–15V DC input; RJ45 connector compatible with various data transmission modules.
Complete Software Suite

Specifications

General Specification
  • Channels: 3
  • Dimensions: φ158 x 160 mm (without spike)
  • Weight: 5.4 kg (included internal battery and spike)
  • Protection Rating: IP68
  • Operating Temperature: -40℃ ~ +70℃
  • Charging Temperature: +3℃ ~ +45℃
  • Charging Time: < 7.5 hrs
  • Battery Life @ 25℃:
    • 40 days @ 2 ms, 24 hrs/day operation
    • 80 days @ 2 ms, 12 hrs/day operation
  • Memory: 64 GB (expandable to 128 GB)
  • Bluetooth QC: Available
  • Data Download: USB 3.0
  • External Power: 7-15 VDC
Channel Specifications
  • (Unless otherwise specified, all values are at a sampling rate of 2 ms, 31.25 Hz, and +25°C)
  • ADC Resolution: 32 bits
    (The ADC offers 32-bit resolution, with a noise-free resolution limited to 24 bits)
  • Sampling Rate: 0.25, 0.5, 1, 2, 4, 8, 10, 20 ms
  • Pre-Amplifier Gain: 0 dB to 36 dB, 6 dB increments
  • Anti-Aliasing Filter: 206.5 Hz @ 2 ms (82.6% of Nyquist); Selectable-Linear Phase or Minimum Phase
  • DC Blocking Filter: 1 Hz to 10 Hz, in 1 Hz increments or DC Removed
  • Maximum Input Signal: ±2.5 V peak @ 0 dB gain
  • Instantaneous Dynamic Range: 125 dB @ 0 dB gain
  • Equivalent Input Noise: 0.18 μV @ 2 ms, 18 dB gain
  • Total Harmonic Distortion: < 0.0002% @ 0 dB gain
  • Common Mode Rejection: > 100 dB
  • Gain Accuracy: < 1%
  • GPS Time Standard: 1 ppm
  • Timing Accuracy: ±10 μs, GPS Synchronization
  • Cross feed: < -110 dB
  • Inter-Channel Phase Difference: < 0.1 ms
  • Transverse vibration suppression: Better than 0.1%
  • Inter-Channel Amplitude Consistency: 5%
  • System Dynamic Range: 145 dB
  • Frequency Response: 0-1652 Hz @ 0.25 ms
Geophone Specifications
  • (Unless otherwise specified, all parameters are tested at +20°C with the vertical core in vertical conditions and the horizontal core in horizontal conditions)
  • Natural Frequency: 2Hz
  • Bandwidth: 15 s ~ 500 Hz
  • Distortion: ≤ 0.30% @ 12 Hz, (0° ~ 7.5° ) vertical tilt, (0° ~ 0.5° ) horizontal tilt
  • Damping: 0.70
  • Sensitivity: 260 V/m/s (6.60 V/in/s)