IGU-16HR 3C 2Hz ETH

IGU-16HR 3C 2Hz ETH
High-Resolution 3C Seismic Node with Low-Frequency and Ethernet Real-Time Data
Precisely Unveiling the Subsurface

Main Features

Integrated Sensor, Digitizer, Communication and Control Capabilities for Efficient and Stable Field Deployment
Built-In DT-SOLO 2Hz Geophone Accurately Captures Deep Low-Frequency Signals
Precision Manufacturing Ensures Accurate and Consistent Instrument Transfer Function
IP68-Rated, Low Power, Long Battery Life, and Ultra-Wide Operating Temperature, Ensuring Reliability in Harsh Conditions
Improves Signal-To-Noise Ratio, Enabling Detection of Ultra-Weak Seismic Signals
Supports Ethernet Communication for Remote Control and Real-Time Data Transmission
Open Data Transmission Protocol Allows Seamless Integration with Mainstream Processing Platforms
Enhanced Circuit Protection Significantly Extends Instrument Lifespan

Peripheral Equipment

• Data download cable with parallel USB 2.0 high-speed data transfer;
• 4-port USB Hub supporting simultaneous data download from 4 devices;
• Power adapter supports 4A current charging;
• Combined power and Ethernet cable supports 7–15V DC input; RJ45 connector compatible with various data transmission modules.

Specifications

General Specification
  • Channels: 3
  • Dimensions: φ158 x 160 mm (without leveling nuts)
  • Weight: 4.8 kg (including battery and leveling nuts)
  • Protection Rating: IP68
  • Operating Temperature: -40℃ ~ +70℃
  • Charging Temperature: +3℃ ~ +45℃
  • Charging Time: < 7.5 hrs
  • Battery Life @ 25℃:
    • 40 days @ 2 ms, 24 hours of operation per day, offline mode;
    • 0 days @ 2 ms, 12 hours of operation per day, offlinef mode;
    • 7 days @ 2 ms, 24 hours of operation per day, Ethernet transmission mode
  • Memory: 64 GB (expandable to 128 GB)
  • Data Transmission: Supports Ethernet data transmission
  • Data Download: USB 2.0
  • External Power: 7-15 VDC
  • GNSS Mode: Support GPS, BEIDOU, GLONASS, with single- mode and dual-mode operation
Channel Specifications
  • (Unless otherwise specified, all values are at a sampling rate of 2 ms, 31.25 Hz, and +25℃)
  • ADC Resolution: 32 bits
    (The ADC has a resolution of 32 bits, with noise resolution not exceeding 24 bits)
  • Sampling Rate: 0.25, 0.5, 1, 2, 4, 8, 10, 20 ms
  • Pre-Amplifier Gain: 0 dB to 36 dB, 6 dB increments
  • Anti-Aliasing Filter: 206.5 Hz @ 2 ms (82.6% of Nyquist); Selectable - Linear Phase or Minimum Phase
  • DC Blocking Filter: 1 Hz to 10 Hz, in 1 Hz increments or DC Remove
  • Maximum Input Signal: ±2.5 V peak @ 0 dB gain
  • Instantaneous Dynamic Range: 125 dB @ 2 ms, 0 dB gain
  • Equivalent Input Noise: 0.18 μV @ 2 ms, 18 dB gain
  • Total Harmonic Distortion: < 0.0002% @ 0 dB gain
  • Common Mode Rejection: > 100 dB
  • Gain Accuracy: < 1%
  • GPS Time Standard: 1 ppm
  • Timing Accuracy: ±10 μs, GPS Synchronization
  • Channel Crosstalk: < -110 dB
  • Inter-Channel Phase Difference : < 0.1 ms
  • Lateral Vibration Suppression: Better than 0.1%
  • Inter-Channel Amplitude Consistency: 5%
  • System Dynamic Range: 145 dB
  • Frequency Response: 0-1652 Hz @ 0.25 ms
Geophone Specifications
  • (Unless otherwise specified, all parameters are tested at +20℃ with the vertical core in vertical conditions and the horizontal core in horizontal conditions)
  • Natural Frequency: 2Hz
  • Distortion: ≤ 0.30% @ 12 Hz, (0° ~ 7.5° ) vertical tilt, (0° ~ 0.5° ) horizontal tilt
  • Damping: 0.70
  • Sensitivity: 260 V/m/s (6.60 V/in/s)